2 If the depth of water entering the water inlet of the inlet pipe is not enough, this will cause vortexes on the water surface around the inlet pipe, affecting the water intake and reducing the amount of water discharged. The correct installation method is: the water depth of small and medium-sized pumps shall not be less than 300-600mm, and the large-sized water pumps shall not be less than 600-1000mm.
Second, the centrifugal pump inlet pipeline elbow pipe plurality <br> <br> If the inlet pipeline with multiple bends, will increase the local flow resistance. And the elbow should be turned in the vertical direction, not allowed to turn in the horizontal direction, so as not to gather air.
Third, the pipeline pump outlet pipe opening above the normal water level in the pool <br> <br> If the outlet in a pool above the normal water level, although increasing pump head, but to reduce the flow. If due to topographic conditions, the water outlet must be higher than the water level of the water tank, then elbows and short pipes should be installed at the nozzle to make the water pipe a siphon type and reduce the outlet height.
Fourth, when installing the water pipeline, the horizontal section is horizontal or upward
This will cause the air in the inlet pipe to collect air, reduce the degree of vacuum in the pipes and the water pump, reduce the pump suction head, and reduce the amount of water output. The correct approach is: The horizontal section should be slightly inclined to the direction of the water source, should not be horizontal, but not upturned.
Fifth, centrifugal Duct <br> <br> does not match the number of pipeline centrifugal pump users think this can improve the actual head, in fact, the actual pump head = total lift ~ loss of lift. When the pump model is determined, the total head is constant; the loss head mainly comes from the pipeline resistance, the smaller the pipe diameter is obviously the greater the resistance, so the greater the loss head, so after reducing the pipe diameter, the actual lift of the pump can not only increase Instead, it will decrease, leading to a drop in pump efficiency. Similarly, when a small-diameter pump uses a large pipe to pump water, it will not reduce the actual head of the pump. Instead, it will reduce the loss head due to a reduction in the resistance of the pipe, which will increase the actual lift. It is also considered that the small-diameter pumps will inevitably greatly increase the motor load when they pump water. They believe that after the pipe diameter is increased, the water in the outlet pipe will have a large pressure on the pump impeller, which will greatly increase the motor load. As everyone knows, the size of the liquid pressure is only related to the height of the head, and has nothing to do with the size of the cross-sectional area of ​​the water pipe. As long as the head is constant, the impeller size of the water pump is constant. Regardless of the diameter, the pressure acting on the impeller is constant. Only after the pipe diameter increases, the flow resistance will decrease, and the flow will increase, and the power consumption will also increase appropriately. But as long as the rated head range, regardless of how to increase the diameter of the pump can work properly, but also can reduce the loss of pipelines, improve the pump efficiency.
Sixth, the centrifugal pump inlet and the elbow pipe is directly connected <br> <br> this would flow past the elbow into the impeller maldistribution. When the inlet pipe diameter is larger than the water pump inlet, an eccentric reducer pipe should be installed. Eccentric reducer tube is to be mounted on the flat surface, and the inclined surface is mounted on the bottom. Otherwise, the air will gather, the amount of water will be reduced or the water will not be pumped, and there will be a crash sound. If the inlet pipe and the water pump inlet diameter are equal, a straight pipe shall be added between the inlet of the pump and the elbow. The length of the straight pipe shall not be less than 2 to 3 times the diameter of the water pipe.
Seven, when the bottom valve is provided, the inlet pipe is not perpendicular to the lowermost stage so as <br> <br> installation, the valve can not turn itself off, resulting in leaks. The correct installation method is: The inlet pipe is equipped with a bottom valve, and the bottom section is preferably vertical. If it cannot be installed vertically due to topographical conditions, the angle between the axis of the water pipe and the horizontal plane shall be 60°
Eight high lift pump for low lift pumping <br> <br> Some users believe that the lower the pipeline centrifugal pumping head, the smaller motor loads. In the misunderstanding of this misunderstanding, when choosing a water pump, the head of the pump is often selected very high. In fact, for the centrifugal pump, when the pump model is determined, the power consumption is proportional to the actual flow of the pump. The flow of the pump will decrease with the increase of the head, so the higher the lift, the smaller the flow and the smaller the power consumption. Conversely, the lower the head, the greater the flow and the greater the power consumed. Therefore, in order to prevent motor overload, it is generally required that the actual pumping head of the pump should not be less than 60% of the rated head. Therefore, when the high head is used for pumping the pump with too low lift, the motor is easily overloaded and generates heat. In severe cases, the motor can be burned. If it is used in emergency, it must be installed on the outlet pipe to adjust the amount of water out of the gate valve (or a small outlet with a small object such as wood) to reduce the flow and prevent the motor from overloading. Pay attention to the temperature rise of the motor. If the motor is found to be overheated, turn off the flow at the outlet or turn off the power immediately. This is also easy to misunderstand. Some operators think that blocking the outlet and forcing a reduction in traffic will increase the motor load. In fact, on the contrary, regular high-power centrifugal pump irrigation units are equipped with gate valves on the outlet pipe. In order to reduce the motor load when the unit is started, the gate valve should be closed first. This is the reason that the gate valve is gradually opened after the motor is started.
Decorative Glass
Decorative glass can be made to customer's design, colored tinted, colored PVB Laminated Glass , with only one color, if with some design, it can be met through Back Painted Glass, Frosted Glass , Silk Printed Glass, Digital Printed Glass, so whatever simple or complicated design for decoration, it can be made; it can also be procesed into laminated glass, Insulated Glass too. Different application with different design, like phot printed, some lines, dots printed for doors, fence, building walls, and also tempered back painted glass for glass wall, kitchen splashback, patio doors, table tops. Frosted glass for shower doos, shower screen, shower partition, office partition walls, room divider, table top, table partition; colored PVB laminated glass for Building Glass walls, windows, doors, partitions, fence, balcony, balustrade, roof, skylight; colorterd tinted glass with its own color, mainly green, grey, blue, brown, can be procesed into color tinted Tempered Glass , color tinted laminated glass, Colored Insulated Glass for windows, doors, glass walls, partitions, balcony railing, balustrade, table top, furniture. So these decorative glass can be used for buildings, glass walls, doors, furniture and so on.